Looking for a quick way to design experiments?
Try the Workflow Configurator. A convenient tool to build experimental workflows and find products to match your needs.

QIAsymphony RNA Kit

For automated purification of total RNA, or total RNA with miRNA, from tissues or cells

S_2682_RPA_QSRNA_s

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

QIAsymphony RNA Kit

Cat. No. / ID:   931636

For as many as 192 preps, depending on protocol: includes 2 reagent cartridges and enzyme racks and accessories
Le QIAsymphony RNA Kit est destiné aux applications de biologie moléculaire. Ce produit n’est pas conçu pour le diagnostic, la prévention ou le traitement des maladies.

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

Features

  • Prefilled reagent cartridges for ease of use
  • High reproducibility through standardized processing
  • Optimized protocols provide high yields of pure RNA
  • Bar codes enable tracking of samples and reagents

Product Details

The QIAsymphony RNA Kit enables automated purification of total RNA, or total RNA including miRNA and other small RNAs, from 1–96 samples on the QIAsymphony SP. Total RNA can be purified from animal cells, tissues, or FFPE tissues, using very small amounts of starting material (≥100 cells) up to 1 x 107 cells or 50 mg of tissue. Optimized protocols provide high yields of pure total RNA, or total RNA including miRNA, and flexible elution volumes allow RNA concentration to be easily optimized for each downstream application. Prefilled reagent cartridges reduce setup time and minimize manual handling. Bar code reading enables full tracking of reagents.

Performance

Automated purification of RNA on the QIAsymphony SP is highly reproducible and yields of high-quality RNA from cultured cells, tissues, and FFPE tissues are comparable to those obtained using a manual purification procedure (see figure " Reproducible purification of RNA"). The QIAsymphony protocols for total RNA purification primarily enrich for RNA molecules longer than 200 nucleotides, including mRNA (see figure " Highly pure, intact RNA"). The QIAsymphony miRNA protocol also purifies total RNA but does not exclude RNAs <200 nucleotides such as miRNAs and other small RNAs (see figure " Automated purification comparable to manual procedure").
See figures

Principle

The QIAsymphony RNA Kit combines the speed and efficiency of silica-based technology with the convenient handling of magnetic particles (see figure " Efficient handling of magnetic particles") for purification of total RNA >200 nucleotides, or total RNA including miRNA and other small RNAs after proteinase K treatment. Starting material includes animal cells and tissues. With some additional components, formalin-fixed paraffin-embedded (FFPE) tissues can also be processed with the kit. Samples are lysed and RNA is purified from lysates in one step through its binding to the silica surface of the particles in the presence of a chaotropic salt. The particles are separated from the lysates using a magnet and DNA is removed by treatment with RNase-free DNase. The magnetic particles are efficiently washed, and RNA is eluted in RNase-free water.
See figures

Procedure

Innovative, ready-to-run reagent cartridges are prefilled with magnetic particles and all reagents required for the purification procedure, including accessory enzymes. The cartridges are automatically opened by the QIAsymphony SP helping to minimize the risk of environmental contamination (see figure " Prefilled, sealed reagent cartridges"). Worktable setup is rapid, which saves your valuable time. Simply place up to 2 reagent cartridges in the consumables drawer. The reagent cartridges can be either from the same kit or from different kits, enabling different purification procedures to be performed within the same run of 96 samples. Reagent volumes only for the selected number of samples are used, giving you complete cost control. The purification procedure comprises 4 steps: lyse, bind, wash, and elute. A number of protocols is available for the QIAsymphony SP for purifying RNA, depending on the starting material and the required RNA product (see table).

Protocols for purification of RNA with the QIAsymphony SP instrument
Protocol Running with Sample material
(Pretreated sample lysates)
Processed volume (μl)
RNA CT 400 QIAsymphony RNA Kit (2 x 96) ≤3 x 106 cultured cells
≤20 mg easy-to-lyse tissue
400 μl
RNA CT 800 QIAsymphony RNA Kit (2 x 48) 3 x 106–1 x 107 cultured cells
≤50 mg easy-to-lyse tissue
800 μl
RNA FT 400* QIAsymphony RNA Kit (2 x 96) ≤20 mg fibrous tissue 400 μl
miRNA CT 400* QIAsymphony RNA Kit (2 x 96) ≤3 x 106 cultured cells
≤20 mg tissue
400 μl
RNA FFPE 130 QIAsymphony RNA Kit (2 x 72) 1–2 x FFPE sections up to 10 μm
1 x FFPE section 20 μm
130 μl
See figures

Applications

The QIAsymphony RNA Kit, and fully automated purification of total RNA on the QIAsymphony SP, provides high-quality RNA suitable for direct use in any downstream application.

Supporting data and figures

Specifications

FeaturesSpecifications
ApplicationsRT-PCR; Real-Time PCR; Expression Profiling
Sample amount400 µl lysate from <20 mg tissue or 3 x 10e6 cells or 800 µl lysate from <50 mg tissue or 3 x 10e6 cells
Elution volume50-200 µl

Resources

Safety Data Sheets (2)
Download Safety Data Sheets for QIAGEN product components.
Application/Protocol Documents (4)
For use with software version 4.0
For use with software version 4.0 or higher 
Labware Documents (1)
For use with software version 4.0
Kit Handbooks (1)
Labware Files and Documents (2)
For use with software version 5.0 or higher
For use with the QIAsymphony SP/AS instruments (software version 4.0)

FAQ

What RNA elution volumes are available with the QIAsymphony RNA Kit?

RNA processed on the QIAsymphony SP with the QIAsymphony RNA Kit can be eluted in 200, 100, or 50 µl.

Elution in smaller volumes will provide higher concentration, but lower overall yield. Total RNA yield with elution in 50 µl will be about 20% lower compared to elution in 100 µl.

 

FAQ ID -1943
What are the starting volumes of homogenate for RNA extraction on the QIAsymphony SP?

Using the Standard protocol for RNA extraction on the QIAsymphony SP, up to 400 µl of lysate can be processed while the Large-Volume protocol allows up to 800 µl of homogenate.

 

 

 

 

FAQ ID -1939
Can I program my own protocols for the QIAsymphony SP?

No. Modified QIAGEN protocols or custom protocols for QIAsymphony SP can be developed to meet your specific requirements and purchased from QIAGEN.

 

 

 

FAQ ID -1904
Can uneven sample numbers be processed on the QIAsymphony SP module?

Yes. Any number of samples between 1 and 96 can be processed on the QIAsymphony SP.

 

 

FAQ ID -1906
Can the QIAsymphony RNA Kit be used to purify RNA from blood?

For purification of RNA from blood on the QIAsymphony SP, we recommend using the QIAsymphony PAXgene RNA Kit, since it includes stabilization of gene expression profiles.

 

 

FAQ ID -1945
Is sample pretreatment required for purifying RNA on the QIAsymphony SP?

For purification of RNA on the QIAsymphony SP, tissue samples require mechanical disruption and homogenization in the supplied lysis buffer (Buffer RLT Plus), e.g., by using the TissueLyser or TissueRuptor. Cultured cells should be lysed by vortexing in the lysis buffer contained in the kit.

 

FAQ ID -1938
What sample input volumes can be used on the QIAsymphony SP?
200–1000 µl sample volumes can be processed on the QIAsymphony Sample Prep Module.
FAQ ID -1907
Is the QIAsymphony RNA Kit compatible with stabilized samples?

Yes, the QIAsymphony RNA Kit is compatible with stabilized samples. We recommend stabilizing tissue samples with RNAprotect Tissue Reagent or AllProtect Tissue Reagent, or by flash-freezing. Cultured cells can be lysed directly in cell culture dishes, or after pelleting. Alternatively, cells can be stabilized using RNAprotect Cell Reagent.


FAQ ID -1944
Which types and amounts of sample material can be processed for RNA extraction on the QIAsymphony SP?

The QIAsymphony RNA Kit enables purification of RNA from cultured cells and easy-to-lyse tissues, such as kidney, liver, and spleen on the QIAsymphony SP. A large-volume protocol is available that enables processing of larger sample amounts.

  • Cultured cells: up to 3x106 cells (standard protocol); up to 1x107 (large volume protocol)
  • Tissues: up to 20 mg of most tissues (standard protocol); up to 50 mg (large-volume protocol)

For particularly DNA-rich tissues, such as spleen or thymus, we recommend either using no more than half the maximum amount, or using DNase at a higher concentration (see the QIAsymphony RNA Handbook; additional DNase required).

FAQ ID -1937
How long can homogenates remain on the QIAsymphony SP without risk of RNA degradation?

Strongly denaturing conditions in the lysis buffer (Buffer RLT Plus) of the QIAsymphony RNA Kit keep RNases in an inactive state. Keeping homogenates on the QIAsymphony instrument at room temperature (20-25°C) for over 6 hours does not impair RNA integrity.

 

FAQ ID -1941
Is it possible to modify QIAsymphony protocols?

No. Protocols on the QIAsymphony SP cannot be modified by users. However, protocols allow elution volumes to be selected within a predefined range. Customized protocols for QIAsymphony SP will be available on request.

 

FAQ ID -1903
What is the range of elution volumes on the QIAsymphony SP?

Depending on the application, elution volumes on the QIAsymphony SP range from 30 µl to 500 µl.

 

 

 

FAQ ID -1908
What are the expected yields of total RNA isolated with the QIAsymphony SP?

Please see expected yields of total RNA isolated with the QIAsymphony RNA Kit on the QIAsymphony SP in the table below:

 

Sample type Sample amount Typical RNA yield (µg)*

Cultured Cells

   
HeLa, Jurkat 1 x 10e6 cells 15

Rat tissues

   
Kidney 10 mg 10-25
Liver 10 mg 20-50
Lung 10 mg 5-10
Spleen 10 mg 25-35

*RNA yields strongly depend on the type and quality of the sample material.

FAQ ID -1942
How many samples can be processed per kit or per reagent cartridge for RNA purification on the QIAsymphony SP?

Each QIAsymphony RNA Kit enables preparation of up to 192 samples (96 per reagent cartridge) using the standard protocol on the QIAsymphony SP. If only the large-volume protocol is used, the number of samples that can be prepared per kit is reduced to 96 (48 per reagent cartridge). Any combination of standard and large-volume sample preparation can be performed.

 

FAQ ID -1940
//dev-homepage/applications/digital-pcr/promotions/registration/search/products?query=QIAGEN%20Plasmid%20Mini%20Kit%20(100/search3/products?query=dna/search3/products/dev-search/products?query=dna/dev-search/products/product-categories/discovery-and-translational-research/genomic-services/product-categories/discovery-and-translational-research/genomic-services?disable-wfc=true&disable-dtm=true/products/products/diagnostics-and-clinical-research/sample-processing/allprep-rnaprotein-kit/products/diagnostics-and-clinical-research/sample-processing/allprep-rnaprotein-kit/products/discovery-and-translational-research/dna-rna-purification/dna-purification/genomic-dna/blood-and-cell-culture-dna-mini-kit/products/discovery-and-translational-research/pcr-qpcr/pcr-enzymes-and-kits/hifidelity-long-range-and-other-pcr/ucp-hifidelity-pcr-kit/products/discovery-and-translational-research/lab-essentials/buffers-reagents/maxtract-high-density/products/discovery-and-translational-research/lab-essentials/buffers-reagents/maxtract-high-density?catno=129056/products/discovery-and-translational-research/lab-essentials/buffers-reagents/maxtract-high-density?catno=129065/products/diagnostics-and-clinical-research/sample-processing/allprep-rnaprotein-kit/BAD_URL/product-categories/discovery-and-translational-research/genomic-services/BAD_URL/products?cmpid=1234&intcmp=456/products?cmpid=asdf&intcmp=qwertysds-searchpromotionsknowledge-and-support/resourcesapplications/enzymes/tools-and-calculatorsapplications/enzymes/tools-and-calculators/ligation-calculator